MAS for advanced system
Model Name/Number 4099-9733
Type Addressable
Minimum Order Quantity 1
Brand Simplex
Description
Digital communication of analog sensing TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. The control unit analyses the data, determines an average value and stores it. Comparing the sensor's present value against its average value and time, determines an alarm or other abnormal condition
Features TrueAlarm analog sensing provides the following features
- Digital transmission of analog sensor values using IDNet or MAPNET II two-wire communications For use with the following Simplex products
- 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control units ; and 4008 Series control units with reduced feature set (refer to data sheet S4008-0001 for details)
- 4020, 4100, and 4120 Series control units, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control unit provides the folloing features
- Peak value logging with accurate analysis of each sensor for individual sensitivity selection
- Sensitivity monitoring meets NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity
- Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent for each foot
- Display and print detailed sensor information in plain English language Photoelectric smoke sensors provide the following features
- Sensitivity levels from 0.2% to 3.1%. See TrueAlarm sensors for more information. Heat sensors have these features
- Three fixed temperature sensing thresholds: 135°F, 155°F and 190°F • Rate-of-rise temperature sensing
- Utility temperature sensing
- Listed to UL 521 and ULC-S530 General features
- Ceiling or wall mounting
- Listed to UL 268 7th Edition and ULC-S529
- NEMA 1 rated. See TrueAlarm analog sensing product selection chart for more information
- .Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted
- Designed for EMI compatibility
- Magnetic testing
- Different bases support a supervised or unsupervised output relay, or a remote LED alarm indicator